Medical clean room lights are specialized lighting equipment for strictly sterile areas such as operating rooms, ICUs, laboratories or microbiology labs. The following article will update the latest price list of clean room lights used in medical clean rooms, helping hospitals and medical centers easily choose standard, safe and effective lighting
- 1. What is a Cleanroom Medical Light? What is it used for?
- 2. Types of LED Lights Used in Cleanroom Medical Facilities
- 3. Cleanroom Medical Light Price List - Updated for 2025
- 4. Recommended Lighting by Area in Cleanroom Medical Facilities
- 5. FAQ - Frequently Asked Questions about Cleanroom Medical Lighting
- 6. Contact Us for Cleanroom Medical Lighting Consultation & Quotation
1. What is a Cleanroom Medical Light? What is it used for?
A cleanroom medical light is a type of lighting fixture specifically designed for environments with strict cleanliness requirements, such as operating rooms, laboratories, isolation rooms, ICUs, microbiology labs, and other medical facilities. Unlike conventional household lighting, cleanroom lights not only ensure consistent illumination but also minimize dust generation, bacterial contamination, and turbulent airflow — all of which could compromise sterility in sensitive medical zones.
Key Roles of Cleanroom Lights in Medical Environments:
- Provide uniform, glare-free lighting to help healthcare professionals perform precise operations.
- Prevent dust accumulation or electrostatic discharge, maintaining clean air integrity.
- Support pressure control, airflow direction, and cleanliness levels according to ISO 14644 or GMP standards.
- Optimize working conditions in areas with high cross-contamination risks.
Technical Requirements for Cleanroom Medical Lights:
- Airtight construction, easy to clean, with no exposed gaps or joints.
- Anti-corrosion and antimicrobial materials; typically stainless steel or powder-coated aluminum housings.
- Color rendering index (CRI) >80, and color temperature between 4000K-6500K, compliant with healthcare lighting standards.
- Flicker-free light with no electromagnetic interference to sensitive medical equipment.
- Certified to TCVN 7114-1:2008, IEC 60598, or ISO cleanroom Class 5-8 standards.
2. Types of LED Lights Used in Cleanroom Medical Facilities
Depending on the specific functional zone, different types of LED cleanroom lights are used in medical environments. Below are the most common models provided by VCR:
Cleanroom LED Panel Lights (Recessed or Surface-Mounted)
Popular Sizes:
- 300x300mm
- 300x600mm
- 300x900mm
- 600x600mm (recessed & surface-mounted)
- 300x1200mm
Technical Features:
- Ultra-slim panel design, evenly diffused light across the surface.
- Powder-coated aluminum housing, anti-dust acrylic/mica lens.
- Easy integration with aluminum cleanroom ceilings or gypsum boards.
- Recessed models suitable for operating rooms, laboratories, and clean zones.
Cleanroom Batten Fixtures (Dual T8 LED Tube Holders)
Popular Sizes:
- 600mm - 2 tubes
- 1200mm - 2 tubes
Technical Features:
- Stainless steel body, corrosion-resistant and easy to sanitize.
- Uses high-performance T8 LED tubes with stable illumination.
- Ideal for high-brightness areas such as pharma warehouses, packing rooms, and sterile zones.
Quick Comparison Table:
Product Name |
Dimensions |
Mounting Type |
Typical Application |
LED Panel 300x300 |
300×300mm |
Recessed ceiling |
Small surgery room, corridor |
LED Panel 600x600 |
600×600mm |
Recessed or surface |
Laboratory, ICU |
LED Panel 300x1200 |
300×1200mm |
Recessed |
Large OR, microbiology lab |
Batten Light 600mm (2 tubes) |
600mm |
Surface-mounted |
Corridor, pharma storage |
Batten Light 1200mm (2 tubes) |
1200mm |
Surface-mounted |
Sterile rooms, compounding areas |
See more: User Guidelines for Cleanroom LED Light
3. Cleanroom Medical Light Price List - Updated for 2025
Below is a reference price list for medical cleanroom lights distributed by VCR. Prices may vary depending on order quantity, technical specifications (e.g., dimmer, CRI, sensor integration), and delivery location.
Light Model |
Size |
Power |
Price (VND) |
LED Panel 300x300 |
12-18W |
840,000 - 960,000 |
Auxiliary areas |
LED Panel 300x600 |
24W |
1,100,000 - 1,260,000 |
Main lighting for compounding areas |
LED Panel 600x600 |
36W |
1,360,000 - 1,560,000 |
Most common for labs and operating rooms |
LED Panel 300x1200 |
48W |
1,700,000 - 1,900,000 |
High brightness areas |
Batten Light 600mm (2 tubes) |
2×18W |
1,380,000 - 1,560,000 |
Flexible tube replacement |
Batten Light 1200mm (2 tubes) |
2×36W |
1,900,000 - 2,300,000 |
Wide light coverage, ideal for cold storage & warehouse |
Note: Prices are for reference only - please contact us for a precise quote based on project drawings and quantity.
4. Recommended Lighting by Area in Cleanroom Medical Facilities
Each functional zone in hospitals and medical centers requires specific lighting performance and cleanroom compliance. Choosing the right fixture helps optimize costs while ensuring ISO 14644 and TCVN 7114 standards are met.
Operating Rooms - ICUs - Sterile Zones
- Requirements: High brightness, glare-free, high CRI (>90), antimicrobial, and zero dust emission.
- Recommended Lights:
Recessed LED Panel 600x600 or 300x1200
IP65 dustproof fixtures or stainless steel batten lights with 2 LED tubes
Laboratories - Microbiology Rooms
- Requirements: Uniform lighting, flicker-free, dust-sealed, and easy to clean.
- Recommended Lights:
LED Panel 300x600 or 600x600 (recessed for panel ceilings)
Neutral white color temperature (4000K-5000K)
Airlocks - Changing Rooms - Waiting Areas
- Requirements: Moderate brightness, energy-efficient, low maintenance.
- Recommended Lights:
LED Panel 300x300 or Batten 600mm - 2 tubes
Surface-mounted models suitable when recessed ceiling is not available
Pharmaceutical Storage - Packaging Zones - Corridors
- Requirements: Large coverage area, wide light spread, cost-effective.
- Recommended Lights:
Batten Light 1200mm - 2 T8 LED tubes or LED Panel 300x1200
Surface or suspended mounting, stainless steel or anti-dust housing
See more: 9 Aspects of LED Light Specification You Need to Understand
5. FAQ - Frequently Asked Questions about Cleanroom Medical Lighting
1. How is a cleanroom medical LED light different from a regular LED light?
Cleanroom medical lights are tightly sealed, dust-free, bacteria-resistant, and made from antimicrobial materials. Additionally, they comply with standards like ISO 14644 and TCVN 7114, designed for use in positive pressure environments to prevent cross-contamination — features that regular LED lights do not offer.
2. Which lights are suitable for ISO 7 or ISO 8 cleanrooms?
For ISO 7-8 cleanrooms, it is recommended to use recessed LED Panel lights (600x600mm or 300x1200mm) with aluminum or stainless steel housing for easy cleaning and non-disruptive airflow. If water resistance is needed, IP65-rated lights are preferable.
3. Can cleanroom LED lights be installed on aluminum panel ceilings?
Yes. Models like LED Panel 300x600, 600x600, and 300x1200mm are designed to fit standard aluminum cleanroom ceiling systems. You can choose between recessed or surface-mounted options depending on your ceiling configuration.
4. What is the lifespan and warranty of cleanroom lights?
The average lifespan ranges from 30,000 to 50,000 hours. VCR offers warranties from 12 to 36 months depending on the light model and usage conditions. Most panel and batten light models are easy to maintain and have replaceable components to reduce maintenance costs.
5. Is lighting certification required after installation in cleanrooms?
Yes. Areas like operating rooms, laboratories, and pharmaceutical compounding zones must meet specific lux levels per ISO and TCVN standards. VCR provides on-site lighting tests to ensure compliance with GMP, ISO 14644, or ISO 17025 certification requirements.
See more: Clean Room Illumination - Strategies to Prevent Contamination
6. Contact Us for Cleanroom Medical Lighting Consultation & Quotation
Are you looking for:
- A detailed quotation for your cleanroom lighting system in hospitals, labs, or ORs?
- Expert advice on selecting lights that meet ISO 14644, TCVN 7114, or GMP-WHO standards?
- Technical support for recessed panel ceiling installation, lux testing, or sensor-integrated lighting?
The VCR team is ready to assist you.
Send us your layout, equipment list, or technical requirements to receive:
- Custom lighting recommendations by functional area
- Detailed quotation with quantity-based discounts
- Coordination with your design or validation team
Hotline: 090.123.9008
Email: [email protected]
Website: https://denphongsach.com/
Diep VCR